http-equiv="content-type" content="text/html; charset=utf-8" /> RIDART - PRODOTTI SETTORE CHIMICO
Select language: ENGLISH
Seleziona la lingua: ITALIANO
Выберите язык: RUSSIAN

WE MADE STAINLESS STEEL SAFETY ACCESSORIES AND VALVES FOR CHEMICAL SECTOR

WE ALSO OFFER A VALID PTFE COATED ALTERNATIVE

WITH STAINLESS STEEL INTERNAL COMPONENTS AND PTFE GASKETS

WHY IT IS IMPORTANT TO USE
AN END OF LINE FLAME ARRESTER
WATCH THE VIDEO

WHY IT IS IMPORTAT TO USE
AN IN LINE FLAME ARRESTER
WATCH THE VIDEO

PRESSURE VACUUM VENT
WITH END OF LINE DEFLAGRATION FLAME ARRESTER
Pressure vacuum vent model 197 can be manufactured both with flame arrester or without it. End-of-line flame arresters contain ribbon coil, an element made of stainless steel that prevents the propagation of the flame inside the tank.
Pressure vacuum vent is normally used in the vapour recovery system (Stage 1) and it is designed to regulate the pressure inside the storage tank and to protect it in case of overpressure.
During normal operation the valve is closed thus helping to reduce the evaporation, saving environment and product loss.

197 EN P SS
2" - 4" - 6"

197 EN P PTFE
2" - 4" - 6"

CLICK HERE TO CHOOSE THE CORRECT FLAME ARRESTER
IN LINE DEFLAGRATION FLAME ARRESTER VALVES
The In Line Flame Arrester Ridart is a Protection System with stainless Steel ribbon coil: deflagration in-line flame arrester in according with Directive 2014/34/EU and harmonized standard EN ISO 16852:2016.
During the filling of a tank, the free vent discharge vapours that may ignite due to atmospheric or accidental causes.
The tank shall be protected to prevent the propagation of flames into the container.
This is the purpose of our Flame Arrester for line deflagration .
Inside there are two ribbon coils certified in stainless steel, which allow the dissipation of flames.

180 EN P PTFE
2"

181 EN P PTFE
3"

330 EN P
STAINLESS STEEL

CLICK HERE TO CHOOSE THE CORRECT FLAME ARRESTER
OVERFILL PREVENTION VALVES
The Overfill Prevention Valve Ridart is designed to prevent the overfill of underground storage tanks by providing a positive shut-off of product delivery

446 SS
2" - 3"

442 PTFE
3"

442 SS
3"

CLICK HERE TO CHOOSE THE CORRECT VALVE
QUICK DRY COUPLINGS AND ACCESSORIES
The RIDART QUICK DRY is used to prevent any possible leaking during the process of transferring fluids during the loading/discharge of tank trucks. There are different materials and sizes.

1602 SS
MALE 3"

QUICK DRY
FEMALE 3"

1600 SS
MALE 2"

1605 SS
FEMALE 2"

RUBBER CAP
DN50




1601 QUICK DRY
MALE 2" 1/2

1700 PTFE
EASY LOCK 3"




ACCESSORIES FOR LOADING LINE
VAPOR STOP RIDART is used to prevent any possible vapors exposure after the cap opening while a liquid drawing operation is in progress.
Vapor stop can be used in different fields of application (petrochemical, food, pharmaceutical & more).
FUTURES: ** Valve opens and closes automatically ** No vapor leakage ** Fast hose emptying (less than 30 seconds) **

SS or PTFE CAPS
3" - 4"

Tappo di carico, cap, plug



SS or PTFE QUICK
ADAPTER 3"-4"

ghiera rapida, quick adapter, lockable plug



93 VAPOR STOP
PTFE 3" - 4"

OVERFILL VALVE
SS or PTFE

ACCESSORIES FOR VAPOR RECOVERY LINE STAGE I

190 SS or PTFE
2" - 3"- 4"

197 EN P
SS or PTFE

180 EN P PTFE
2"

120 B PTFE
VAPOR RECOVERY

BALL FLOAT VENT VALVES - VAPOR RECOVERY LINE STAGE II
The RIDART BALL FLOAT VALVE is normally used in the vapor recovery line (Stage 2). It is designed to protect the vapor recovery line from fuel overfilling hazard during loading operation.
There are different sizes and models also with FLAME ARRESTER. Flame arrester element is designed to isolate flames and protect a circumscribed area.

1010 EN P
PTFE 2"

ACCESSORIES FOR SUCTION LINE
The ANGLE CHECK VALVE is a device in according with Directive 2014/34/EU and harmonized standard.
This valve is designed to prevent the drainage of fuel (loss of prime) in the suction line and permits the product flowing only towards a dispenser.
The valve is installed on the manhole lid of the storage tank.

The CHECK VALVE is designed to prevent the back flow of fluid on the suction line and permits its flow only in one direction.

40 SS
FILTER 1"1/2 - 2"

60 SS 2"
ANGLE CHECK VALVE

60 PTFE 2"
ANGLE CHECK VALVE

20 SS 1" -1" 1/2 - 2"
CHECK VALVE

EMERGENCY SHEAR VALVES
The single and double poppet emergency SHUT-OFF VALVE is installed in the fuel delivery line and is designed to protect from danger of product loss by closing the flow of fuel in case of accident, damage or fire.
Double poppet shut-off valve allows the closure of both lines from the underground storage tank (inlet) and to dispenser (outlet).
The valve allows full flowing capacity with normal operation.

23 PTFE
SHUT-OFF VALVE

31 SS
SHEAR VALVE




MEASURING ACCESSORIES

DIPSTICK
STAINLESS STEEL

GAUGING PLUG
STAINLESS STEEL

GAUGING PLUG
PTFE

ANTI-SIPHON VALVES
The ANTI-SIPHON VALVE is designed to prevent siphoning of liquid from an aboveground tank to the suction pipe installed at a lower level.
The valve does not permit the fuel to come out from the dispenser when it is not working.

55 B PTFE
ANTI-SIPHON VALVE

1510 B PTFE
ANTI-SIPHON VALVE

Messaggia su WhatsApp