Select language: ENGLISH
Seleziona la lingua: ITALIANO
Выберите язык: RUSSIAN

3D VIDEO
VAPOR RECOVERY LINE
STAGE I

3D VIDEO
VAPOR RECOVERY LINE
STAGE II

PRESSURE VACUUM VENT
WITH END OF LINE DEFLAGRATION FLAME ARRESTER
Pressure vacuum vent model 197 can be manufactured both with flame arrester or without it. End-of-line flame arresters contain ribbon coil, an element made of stainless steel that prevents the propagation of the flame inside the tank.
Pressure vacuum vent is normally used in the vapour recovery system (Stage 1) and it is designed to regulate the pressure inside the storage tank and to protect it in case of overpressure.
During normal operation the valve is closed thus helping to reduce the evaporation, saving environment and product loss.

197 EN P
ALUMINIUM

197 EN P SS
STAINLESS STEEL

197 EN P
PTFE

197 SM
NO SPRING

197 EN P
VENT

197 STANDARD
PRESS/DEPRESS

CLICK HERE TO CHOOSE THE CORRECT FLAME ARRESTER
IN LINE DEFLAGRATION FLAME ARRESTER VALVES
The In Line Flame Arrester Ridart is a Protection System with stainless Steel ribbon coil: deflagration in-line flame arrester in according with Directive 2014/34/EU and harmonized standard EN ISO 16852:2016.
During the filling of a tank, the free vent discharge vapours that may ignite due to atmospheric or accidental causes.
The tank shall be protected to prevent the propagation of flames into the container.
This is the purpose of our Flame Arrester for line deflagration .
Inside there are two ribbon coils certified in stainless steel, which allow the dissipation of flames.

180 EN P
BRASS

181 EN P
BRASS

182 EN P
BRASS

330 EN P
ALUMINIUM

330 EN P SS
STAINLESS STEEL

180/181 EN P
PTFE

425 EN P
ALUMINIUM

CLICK HERE TO CHOOSE THE CORRECT FLAME ARRESTER
OVERFILL PREVENTION VALVES
The Overfill Prevention Valve Ridart is designed to prevent the overfill of underground storage tanks by providing a positive shut-off of product delivery

446 2" - 3"
ALUMINIUM

442 3"
ALUMINIUM

442 SS 3"
STAINLESS STEEL

442 B 3" - 4"
ALUMINIUM

442 S
SHORT

442 OR
HORIZONTAL

CLICK HERE TO CHOOSE THE CORRECT OVERFILL PREVENTION VALVE
API ADAPTER FUEL TRANSFER VALVES
The adapter API RP 1004 is used to prevent any possible leaking during the process of transferring fluids during the loading/discharge of tank trucks.
There are different versions of the adapter, with and without a lever for manual opening and different sizes.

1521 FEMALE
API ADAPTER




1527 MALE
API ADAPTER




1527 L WITH LEVER
API ADAPTER MALE




1526 FEMALE
API ADAPTER




1526 R WITH LEVER
API ADAPTER FEMALE




1528 ALUMINIUM
DUST CAP API




1528G RUBBER EPDM
DUST CAP API




QUICK DRY COUPLER FUEL TRANSFER VALVES
The RIDART QUICK DRY is used to prevent any possible leaking during the process of transferring fluids during the loading/discharge of tank trucks.
There are different materials and sizes.

1602 SS
MALE 3"

QUICK DRY
FEMALE 3"

1600 SS
MALE 2"

1605 SS
FEMALE 2"

RUBBER CAP
DN50




VAPOR RECOVERY ADAPTER
CAMLOCK COUPLINGS
RIDART VAPOR RECOVERY ADAPTER are normally used in the vapour recovery line (Stage 1). Upon its connection with a camlock coupling, the valve opens allowing the vapor to return to the tank truck.
There are different sizes and models also with flame arrester. Flame arrester element is designed to isolate flames and protect a circumscribed area.

1520 CAMLOCK
FEMALE ALUMINIUM




1524 ENP
3"FX4"M CAMLOCK

1534 ENP
3"FX3"M CAMLOCK

1525 VR
2"-3"-4"FX4"M CAMLOCK

1535
3"FX3"M CAMLOCK

1528 CL
CAMLOCK CAP




ACCESSORIES FOR LOADING LINE
VAPOR STOP RIDART is used to prevent any possible vapors exposure after the cap opening while a liquid drawing operation is in progress.
Vapor stop can be used in different fields of application (petrochemical, food, pharmaceutical & more).
FUTURES: ** Valve opens and closes automatically ** No vapor leakage ** Fast hose emptying (less than 30 seconds) **

CAPS

Tappo di carico, cap, plug



COUPLINGS

ghiera rapida, quick adapter, lockable plug



ANTI-THEFT GRID

griglia antifurto, fastenable closing



VAPOR STOP 4"

OVERFILL VALVES

ACCESSORIES FOR VAPOR RECOVERY LINE STAGE I

190 VENT BRASS
ALUMINIUM or SS

1524/1534 EN P
VAPOR RECOVERY

197 EN P
PRESSURE VALVE

180 EN P IN LINE
FLAME ARRESTER

120B BRASS
VAPOR RECOVERY

BALL FLOAT VENT VALVES - VAPOR RECOVERY LINE STAGE II
The RIDART BALL FLOAT VALVE is normally used in the vapor recovery line (Stage 2). It is designed to protect the vapor recovery line from fuel overfilling hazard during loading operation.
There are different sizes and models also with FLAME ARRESTER. Flame arrester element is designed to isolate flames and protect a circumscribed area.

1010
ALUMINIUM

1010 EN P
FLOATING VALVE

1015
FLOATING VALVE

ACCESSORIES FOR SUCTION LINE
The ANGLE CHECK VALVE is a device in according with Directive 2014/34/EU and harmonized standard.
This valve is designed to prevent the drainage of fuel (loss of prime) in the suction line and permits the product flowing only towards a dispenser.
The valve is installed on the manhole lid of the storage tank.

The CHECK VALVE is designed to prevent the back flow of fluid on the suction line and permits its flow only in one direction.

10 FOOT VALVE
BRASS

50 FILTER
BRASS

15 UNDER PUMP
CHECK VALVE

55 ADJUSTABLE
CHECK VALVE

60 GH
ANGLE CHECK VALVE

60 OT
BRASS

60 SS
STAINLESS STEEL

60 R
CHECK VALVE

62 ANGLE
CHECK VALVE

21 BRASS
CHECK VALVE

20SS CHECK VALVE
STAINLESS STEEL

EMERGENCY SHEAR VALVES
The single and double poppet emergency SHUT-OFF VALVE is installed in the fuel delivery line and is designed to protect from danger of product loss by closing the flow of fuel in case of accident, damage or fire.
Double poppet shut-off valve allows the closure of both lines from the underground storage tank (inlet) and to dispenser (outlet).
The valve allows full flowing capacity with normal operation.

30 SHEAR
CHECK VALVE

25
SHEAR VALVE

23 / 26
SHUT-OFF VALVE

27 / 28
SHUT-OFF VALVE

2510 BRASS
SHEAR VALVE

31 SS
STAINLESS STEEL




ABOVEGROUND STORAGE TANK
The ANTI-SIPHON VALVE is designed to prevent siphoning of liquid from an aboveground tank to the suction pipe installed at a lower level.
The valve does not permit the fuel to come out from the dispenser when it is not working.

1510 ANTI-SIPHON
VALVE ALUMINIUM

55B ADJUSTABLE
CHECK VALVE

198 ACTIVE
COAL VENT

60 B ANGLE
CHECK VALVE




NEW: PRESSURE VACUUMM VENT WITH ROLL-OVER PROTECTION
It is designed to prevent the overpressure inside tank trucks, its function is to re-establish the correct pressure and to avoid the leak of liquids.
In addition, the valve installed on mobile tanks and tank trucks has a roll-over protection system that is activated at any angle check than 30° from the vertical position.
It is important to known the pressure/vacuum parameters. Different settings may be required.

197B3
ALUMINIUM




193 ALUMINIUM
EMERGENCY VALVE




193 SS
EMERGENCY VALVE




197AT VACUUM VENT
ROLL-OVER

197-400 PRESSURE
VACUUM VENT




MEASURING ACCESSORIES

DIPSTICKS
ALUMINIUM

asta metrica, dipstick

GAUGING PLUG
BRASS

sede asta metrica, gauging plug

DIPSTICKS
STAINLESS STEEL

GAUGING PLUG
STAINLESS STEEL

FUEL LEVEL
DETECTION PASTE

WATER DETECTION
PASTE

LEVEL MONITORING
ASSEMBLED

OTHER

431 GATE
VALVE

230 SS SWIVEL
JOINT SS