Select language: ENGLISH
Seleziona la lingua: ITALIANO
Выберите язык: RUSSIAN
PRESSURE VACUUM VENT
WITH END OF LINE DEFLAGRATION FLAME ARRESTER
Pressure vacuum vent model 197 can be manufactured both with flame arrester or without it. End-of-line flame arresters contain ribbon coil, an element made of stainless steel that prevents the propagation of the flame inside the tank.
Pressure vacuum vent is normally used in the vapour recovery system (Stage 1) and it is designed to regulate the pressure inside the storage tank and to protect it in case of overpressure.
During normal operation the valve is closed thus helping to reduce the evaporation, saving environment and product loss.

197 EN P
ALUMINIUM

197 EN P SS
STAINLESS STEEL

197 EN P
PTFE

197 EN P
VENT

CLICK HERE TO CHOOSE THE CORRECT FLAME ARRESTER
IN LINE DEFLAGRATION FLAME ARRESTER VALVES
The In Line Flame Arrester Ridart is a Protection System with stainless Steel ribbon coil: deflagration in-line flame arrester in according with Directive 2014/34/EU and harmonized standard EN ISO 16852:2016.
During the filling of a tank, the free vent discharge vapours that may ignite due to atmospheric or accidental causes.
The tank shall be protected to prevent the propagation of flames into the container.
This is the purpose of our Flame Arrester for line deflagration .
Inside there are two ribbon coils certified in stainless steel, which allow the dissipation of flames.

180 EN P
BRASS

181 EN P
BRASS

182 EN P
BRASS

330 EN P
BRASS

330 EN P SS
STAINLESS STEEL

180/181 EN P
PTFE

425 EN P
ALUMINIUM

CLICK HERE TO CHOOSE THE CORRECT FLAME ARRESTER
VAPOR RECOVERY ADAPTER
CAMLOCK COUPLINGS
RIDART VAPOR RECOVERY ADAPTER are normally used in the vapour recovery line (Stage 1). Upon its connection with a camlock coupling, the valve opens allowing the vapor to return to the tank truck.
There are different sizes and models also with flame arrester. Flame arrester element is designed to isolate flames and protect a circumscribed area.

1520 CAMLOCK
FEMALE ALUMINIUM




1524 ENP
3"FX4"M CAMLOCK

1534 ENP
3"FX3"M CAMLOCK

1528 CL
CAMLOCK CAP




BALL FLOAT VENT VALVES - VAPOR RECOVERY LINE STAGE II
The RIDART BALL FLOAT VALVE is normally used in the vapor recovery line (Stage 2). It is designed to protect the vapor recovery line from fuel overfilling hazard during loading operation.
There are different sizes and models also with FLAME ARRESTER. Flame arrester element is designed to isolate flames and protect a circumscribed area.

1010 EN P
ALUMINIUM e PTFE